WEIGHT VISUALIZER for load cells
Indicator of weight with input for cargo cells or input 0-10V or 4-20mA.
Numerical Display to 6 characters/figures, height 60 mm, container in stainless steel and watertight logons.
Configuration and calibration from remote control, serial trasmition Rs232, Rs485. RF868Mhz extern interface (optional).
Download installation and usage manual
Click to enlarge image
Power supply | 230 - Opz. 115 Vac 50/60 Hz | |
Max power consumption | 10 W | |
Operating temperature | -10 / +40°C (14 °F / 104°F) Humidity maximum 85% non-condensing | |
Storage temperature | -20 / +50°C (-4 / +122°F) | |
Display | High efficiency 6-digit numerical LED and wide viewing angle, reading distance up to 50 feet | |
Reading distance | Till at 15 m | |
Visualized data | Weight acquired from cells or analogue input 0-10V/4-20 mA, alphanumeric indications/programming menu | |
Functions remote control | Tare entry / cancellation, zero scale, serial transmission current weight, configuration and calibration | |
Overall dimensions | 320 x 110 x 90 mm /12.6 x 4.3 x 3.5 in (l x h x p) | |
Mounting | Wall-mounted with 4 external side holes Ø 6 mm with center distance 340 x 80 mm (l x h) | |
Case material | Stainless steel protected against dust | |
Protection level | IP 65 | |
Connections | Waterproof circular connectors with conductor wiring with screw terminal | |
Power supply load cells | 5 V dc / 120 mA (maximum 8 cells with 350 Ω in parallel) protected against short-circuit | |
Linearity | < 0.01% of full scale | |
Temperature deviation | <0,0003% of full scale/°C | |
Internal resolution | 24 bit | |
Weight resolution | Up to 60,000 divisions on the load capacity | |
Measuring range | -1.5 mV/V - +3.5 mV/V | |
Weight acquisition frequency | 6 Hz - 25 Hz | |
Digital filter | 0.2 Hz - 25 Hz | |
Number of weight decimals | from 0 to 3 decimal digit | |
Communication ports | Rs232c / Rs485 standard | |
Max. cable length | 15m (Rs232c) and 1000m (Rs485) | |
Serial protocols | ASCII + custom protocols | |
Baud rate | From 1200 to 115200 selectable | |
Remote control | 4-key remote control for configuration and operational commands | |
Options | External 868 MHz RF interface, Ethernet protocol, Profibus protocol | |
Conforms to standards | EN61000-6-2, EN6100-6-3, EN61010-1 |
Type | J1 5 poles serial female |
Length | ND |
1 | GND + Shield |
2 | RS232 Rx |
3 | RS485 - |
4 | RS485 + |
5 | RS232 Tx |
Type | J2 5 poles male load cell |
Length | ND |
1 | + Exc. Load cell |
2 | + signal load cell |
3 | - Signal load cell |
4 | - Exc. Load cell |
5 | Shield |
Type | J3 7 poles male optional outputs |
Length | ND |
1 | Out 1 NA |
2 | Out 1 NC |
3 | Out 2 NA |
4 | Out 2 NC |
5 | Out 3 NA |
6 | Out 3 NC |
7 | Common output |
General precautions to be followed in the installation and assembly of load cells: